How Freezing Temperatures Impact Your Backflow Preventer and What You Can Do



Backflow preventers are critical components of your plumbing system, safeguarding your potable water supply from contamination. While designed for durability, these devices are vulnerable to the harsh realities of freezing weather.


A frozen backflow preventer can lead to costly repairs, water damage, and potential health hazards. This blog post delves into the specific ways freezing temperatures affect backflow preventers, explores proactive preventative measures often overlooked, and provides practical advice to protect this vital piece of your plumbing infrastructure during winter's chill.


Understanding the Vulnerability


Backflow preventers, regardless of type (double check valve, reduced pressure principle, etc.), contain internal components susceptible to damage from freezing. Water expands as it freezes, exerting immense pressure on the device's internal chambers, seals, and valves. This pressure can:


  • Crack or Break Internal Components: The expansion of ice can fracture delicate internal parts, rendering the backflow preventer ineffective and potentially causing leaks. This damage may not be immediately apparent, leading to future contamination risks.

  • Damage Seals and O-rings: Freezing can cause seals and O-rings to become brittle and crack, compromising the watertight integrity of the device. This can lead to leaks and the potential for backflow.

  • Warp or Distort the Body of the Device: The intense pressure from expanding ice can warp or distort the physical structure of the backflow preventer, affecting its proper functioning and potentially requiring replacement.

  • Cause Internal Blockages: If water freezes within the internal passages, it can create blockages that prevent the proper flow of water, leading to reduced water pressure or complete system failure.


Beyond the Obvious: Uncommon Freezing Scenarios and Their Impact


While most people focus on the obvious – freezing water within the device – other less-considered scenarios can also cause damage:


  • Freezing in the Piping Leading to the Preventer: Frozen pipes upstream of the backflow preventer can create a pressure build-up that damages the device, even if the water inside the preventer itself doesn't freeze. This is especially relevant for devices located in exposed or poorly insulated areas.

  • Ground Water Freezing Around the Device: In extremely cold climates, the ground surrounding the backflow preventer can freeze, causing contraction and stress on the device's connections and piping. This can lead to cracks and leaks.

  • Improper Installation: Incorrect installation, including inadequate drainage or insufficient insulation, significantly increases the risk of freezing damage. Improperly installed devices are more prone to holding water that can freeze.

  • Type of Backflow Preventer: Different types of backflow preventers have varying degrees of vulnerability. For instance, devices with larger internal chambers or more complex mechanisms may be more susceptible to freezing damage.


Preventative Measures: Going Beyond Simple Insulation


While insulating the backflow preventer is crucial, a comprehensive approach is necessary:


  • Proper Drainage: Ensure that all pipes leading to and from the backflow preventer are properly sloped to facilitate drainage and prevent water from pooling within the device. This prevents water from remaining stagnant and more susceptible to freezing.

  • Advanced Insulation: Go beyond basic insulation. Consider using heat tape or heat tracing cables to maintain a consistent temperature around the backflow preventer and its associated piping. These offer active temperature control, preventing freezing even in extremely cold conditions.

  • Regular Inspection and Maintenance: Schedule routine inspections of your backflow preventer, especially before and after periods of freezing temperatures. Look for any signs of damage, leaks, or ice buildup. Professional testing and certification are essential to ensure functionality.

  • Water Meter Pit Protection: If the backflow preventer is located in a water meter pit, ensure the pit is properly insulated and protected from the elements. Consider adding extra insulation layers to the pit walls and cover.

  • Automatic Drain Valves: Install automatic drain valves on the backflow preventer to allow for the complete draining of water from the device during periods of freezing temperatures. This eliminates the risk of internal freezing.


Conclusion


Protecting your backflow preventer from freezing temperatures is a crucial aspect of maintaining the safety and integrity of your water supply. While insulation is a fundamental step, a proactive and comprehensive approach is essential to mitigate the risk of damage.


By implementing the preventative measures discussed, including proper drainage, advanced insulation techniques, regular inspections, and the consideration of automatic drain valves, you can significantly reduce the likelihood of costly repairs and ensure the continued protection of your potable water system throughout the winter months. Remember, prevention is far more cost-effective than remediation. Investing in the protection of your backflow preventer is an investment in the safety and reliability of your entire plumbing system.

 
 
 

Comments


Sunday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

WORKING HOURS

Monday - Friday

7:00AM - 4:00PM for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

Saturday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

VISIT US

ATLAS BACKFLOW INC.

1101 East 25th Street, Signal Hill, CA 90755

Office: (562) 343-1436 

Cell: (562) 304-3069

 

(Call or Text 24 hr's a day)

C-36 #1088210

  • Yelp
  • Facebook

GET IN TOUCH

Thanks for submitting!

© 2020 by The Media Boom

bottom of page